Talk to us
Office
Mumbai: No. 143, Satra Plaza, Palm Beach Road, Sector 19D, Vashi, Navi Mumbai – 400703 Ph: +91 (22) 27833430
Help
Visit Help Center
Follow us
WGT
What we offer
At UHP Technologies, we understand the critical importance of managing harmful gases within process areas and preventing their release into the environment. We offer comprehensive turnkey solutions for the treatment of hazardous gases.
Our Consultancy Services Include:
- Hot Air Exhaust Stream
- Acid & Alkali Exhaust Stream
- VOC Exhaust Stream
- Vacuum Piping and Back Filters
- Hot Air Exhaust
Thermal tools in the semiconductor industry generate significant heat. We provide complete solutions from the tool to the atmosphere, ensuring all safety precautions are met.
- Acid & Alkali Exhaust
Chemicals used in these tools often operate at higher temperatures, increasing the rate of vaporization. These hazardous chemicals pose health and safety risks within the process area and can cause environmental damage if untreated. We design and implement comprehensive treatment systems to manage these gases effectively.
- VOC Exhaust
Solvent tools used in the semiconductor and PV industries produce high amounts of volatile organic compounds (VOCs). These compounds are incinerated after application to the wafer surface. Based on the concentration produced, we offer turnkey solutions for adsorption systems.
- Vacuum Piping and Back Filters
We provide solutions for vacuum piping from Semiconductor tools to Vacuum pumps and Local abatement systems. Additionally, we offer scrubbers for abatement systems that may release untreated effluent air.
At UHP Technologies, we ensure the effective management of effluent gases from the tool to the atmosphere, providing our customers with reliable and efficient solutions.
Code | Description |
ASHRAE Fundamental Handbook 2017 | |
ASHRAE -Applications Handbook 2019 | |
ASHRAE Systems and Equipment Handbook 2020 | |
ASHRAE Standard 62.1:2019 | Ventilation of Acceptable Indoor Air Quality standards |
AMCA 204: 2012 | Balance Quality and Vibration Levels for Fans |
AMCA 210 2016 | Laboratory Methods of Testing Fan for Rating Purposes |
ANSI/AHRI 575: 2017 | Method of Measuring Machinery Sound within an Equipment Space |
ASME B16.5.2020 | Pipe flanges and flanged fittings |
IS 1520-1980 |
|
IS 659: 1964 | Safety Code for Air conditioning |
IS 2494: 1994 | V-Belts for Industrial Purposes |
IS 3142 2000 f | V-Grooved Pulley |
IS 655: 2006 | Metal Air ducts |
IS 277: 2003 | Galvanized Steel Sheets (Plain and Corrugated) |
IS 1239 (Part 1): 2004 | Mild Steel Tubes |
IS 3589: 2001 | Seamless or electrically welded steel pipes for water, gas, and sewage. |
1S 2379: 1990 | Colour Code for Identification of Pipelines. |
IS: 2062: 2011 | Steel for General Structural Purposes. |
IS: 2062: 2011 | Steel for General Structural Purposes. |
IS: 3103: 2008 | Code of Practice for Industrial Ventilation |
IS 4894: 1987 | Test Code for Centrifugal Fans |
IS: 4894 | Test Code for Centrifugal Fans. |
AMCA-210 | Laboratory Method of Testing Fans for rating purposes. |
NBC: 2016 | National Building Code of India |
IS-226 | Structural steel. |
IS:1239(Part 1)-1990 | Mild Steel Tube |
IS 3589 Fe 410 grade: | MS piping |
48 IS:1239 (Part II) 1992 | Mild Steel Tubular and other wrought steel pipe fittings. |
ANSI B16.34 | Steel body gate, globe, angle, and check valves |
ANSI B31.1 | Steel body gate valve below 50 mm. |
IS: 780-1984 52 IS-2825 | Sluice Valves for water works purposes |
Code of practice for welding mild steel | |
IS-822-1970 (Reaffirmed 1991) | Code of Procedure for inspection of welds. |
IS:554-1985 (Reaffirmed 1996) | Dimensions for pipe threads where press |
tight joints are reqd, on the threads | |
IS: 2379-1990 | Colour code for the identification of pipe |
IS-3103-1975 | Code of practice for industrial ventilation |
IS:4736-1986 | Hot-dip zinc coatings on steel tubes |
IS: 5312(Part-1) 1984 | Check type reflux Non-Return (Reaffirmed 1990) swing. Valves for water works |
IS: 6392-1971 (Reaffirmed 1988) | Steel pipe flanges |
IS-702 | Industrial bitumen. |
IS: 4894 | Centrifugal fans |
1S: 277 | Galvanized Steel Sheets |
IS 655 | Metal Air ducts |
1S 3103 | Code of practice of Industrial Ventiation |
UL 555 | Fire dampers |
IS 325 | Three phase induction motors |
BS: 848 | Method of performance test for centrifugal fans |
AMCA 210 | Test code for air moving devices |
IS: 325 | Three phase induction motors |
IS: 7098 Part-1 | Power cables |
IS: 1554 Part-1 |
|
IS: 4237 | MCC |
IS: 6875 | PB Stations |
IS 3103 | Code of practice of Industrial Ventilation |
AMCA 210 | Test code for air movement device |
IS 2312 | Propeller type AC ventilation fans |
IS 4894 | Centrifugal fans |
IP-65 | Motor Protection |
NBC-Part-4 | National building code part 4 |
ASHRAE 15 | Safety Code for Mechanical Refrigeration |
ASHRAE 62.1 | Indoor Air Quality |
ASHRAE Standard 55: | Thermal comfort |
IS 3677 | IS 3677 |
IS 8183 | IS 8183 |
IS 9842 | IS 9842 |
IS 14164 | IS 14164 |
ASHRAE 90.1 | Energy Standard for Buildings except Low-Rise Residential Buildings |